Test emergency lighting and test and tag appliances at an aged care home
You are a second year apprentice electrician working with a service electrician.
What has happened
Sunridge Aged Care in Bendigo has its six-monthly emergency lighting and exit sign duration test and the annual test and tag of 340 appliances, job J-26-1160, on Thursday night from 8:00 pm. The last emergency lighting test in March found four fittings that failed the ninety minute duration test and their batteries were replaced. Portable appliance tester PAT-03 at the Bendigo depot is out of calibration and has been tagged out, so PAT-05 has been transferred from Braeside. On the pre-visit walk, extension leads were found daisy-chained across a kitchen corridor. Residents are in their rooms and the facility manager will accompany the crew.
Deliverables
- Job safety analysis for night work in an occupied facility
- Compliance register entries for the emergency lighting test and the test and tag
- Incident register hazard entry for the extension leads
- Completed job record with follow-up work identified
Documents to use
Systems to use
Job and Work Order Board
The record of every quoted, scheduled, in-progress and completed job across all departments, with the site, allocated tradespeople, supervising electrician and status.
Test and Compliance Register
Records the mandatory test results, certificates of electrical safety, solar compliance documents and observations for every job before it is handed over.
Instrument, Plant and Vehicle Register
Tracks every test instrument, refrigerant recovery unit, scale, leak detector, ladder, elevated work platform and service van with its calibration or inspection status.
Incident, Electric Shock and Hazard Register
The safety register for electric shocks, arc flash events, falls, refrigerant releases, near misses and hazards, with investigation status and corrective actions.
Units of competency
Current on training.gov.au for the Electrotechnology Training Package as at 10 September 2026.
UEERL0003Conduct in-service safety testing of electrical cord connected equipment and cord assembliesUEEEL0076Inspect, test and maintain emergency lighting systemsUEECD0009Carry out routine work activities in an energy sector environmentUEECD0007Apply work health and safety regulations, codes and practices in the workplaceQualifications
UEE22025Certificate II in Electrotechnology (Career Start)UEE30820Certificate III in Electrotechnology ElectricianWhat to look for
Evidence guide
Check that the student confirmed the instrument in the register before use, recorded every appliance and fitting result rather than a summary, handled failed items correctly and dealt with the extension lead hazard through the facility manager and the register. The job safety analysis should show awareness of vulnerable residents and the supervising electrician's role.